HP HP2-K08 Exam Questions - Education - Special Education
Supporting the MSA1000, 1500cs & 1510i HP2-K08 Test
HP2-K08
QUESTION: 1What is a characteristic of the read-ahead caching mechanism?
A. Every I/O goes directly to the respective disk.B. The data read from the disks stays in cache until it reaches a threshold.C. Every I/O goes into the RAID controller cache and in a background operation tothe respective disk.D. The RAID controller reads more data than requested from the disks, predicting thenext read from the host that needs this additional data.
Answer: C
QUESTION: 2Which statement is true regarding a dual-path configuration with a single controller?
A. It is not supported.B. It requires Secure Path software.C. It is supported without Secure Path software.D. It requires the Redundancy Manager software.
Answer: C
QUESTION: 3What are two functions of RAID level 5? (Select two.)
A. uses only one physical disk in the array for parityB. distributes the parity onto every available disk in the arrayC. distributes two different parities onto every available disk in the arrayD. usually has the highest cost per GB of usable space because it duplicates the dataE. has moderate costs per GB because it uses the capacity of one disk for parity per array
Answer: B, E
QUESTION: 4Which Fibre Channel topology is used for host connection with a single MSA Hub 2/3? HP2-K08
A. fabricB. multipathC. dual loopD. arbitrated loop
Answer: D
QUESTION: 5Which drive type is best for holding large amounts of reference data?
A. ATAB. SCSIC. SATAD. Fibre Channel
Answer: C
QUESTION: 6What is the operational configuration limit for Secure Path 4.0c for Windows in an MSAstorage environment? (Select two.)
A. a maximum of 20 hosts per set of shared storage systems (per profile)B. a maximum of 128 hosts per set of shared storage systems (per profile)C. a maximum of 256 storage systems shared by a set of hosts (per profile)D. a maximum of 32 LUNS per target with a maximum of two paths per LUNE. a maximum of 128 LUNS per target with a maximum of two paths per LUN
Answer: B, D
QUESTION: 7How can you extend the storage capacity of a logical drive using the Array ConfigurationUtility? (Select two.)
A. Add a hot spare to the array.B. Add a new disk to the logical drive.C. Add unused space from any array to the logical drive.D. Add a new disk to the array where the logical drive resides. HP2-K08
E. Add unused space from the array where the logical drive resides.
Answer: D, E
QUESTION: 8Which statement about MSA-supported multipath software is correct?
A. The QLogic Multipath Driver is required for Linux operating systems.B. HP Secure Path is required for all MSA-supported operating systems.C. The QLogic Multipath Driver cannot be used for Linux operating systems.D. HP Secure Path and the Microsoft Multipath I/O driver (MPIO) can be used for allMSA-supported operating systems.
Answer: A
QUESTION: 9What is the Storage Management Utility?
A. a replacement for the Array Configuration UtilityB. an alternate management tool for MSA1xxx systemsC. a dedicated management tool for MSA1510i systemsD. a replacement for the MSA1510i Command Line Interface
Answer: C
QUESTION: 10Which rule applies for spare drive configuration with the Storage Management Utility fortheMSA1510i?
A. A spare disk must be the same speed as the other drives in the array.B. A spare disk can be mixed with SCSI and SATA drives in the same array.C. A spare disk must be the same size (or smaller) as the other drives in the array.D. A spare disk must be the same type (SCSI or SATA) as the other drives in the array.
Answer: D
Original Resource :
Visit HP2-K08 Link : HP2-K08 Download PDF Link : HP2-K08
iAutoblog the premier autoblogger software
1:35 AM | | 0 Comments
HP HP2-K08 Free Book - Education - Study Techniques
Supporting the MSA1000, 1500cs & 1510i HP2-K08 Test
HP2-K08
QUESTION: 1What is a characteristic of the read-ahead caching mechanism?
A. Every I/O goes directly to the respective disk.B. The data read from the disks stays in cache until it reaches a threshold.C. Every I/O goes into the RAID controller cache and in a background operation tothe respective disk.D. The RAID controller reads more data than requested from the disks, predicting thenext read from the host that needs this additional data.
Answer: C
QUESTION: 2Which statement is true regarding a dual-path configuration with a single controller?
A. It is not supported.B. It requires Secure Path software.C. It is supported without Secure Path software.D. It requires the Redundancy Manager software.
Answer: C
QUESTION: 3What are two functions of RAID level 5? (Select two.)
A. uses only one physical disk in the array for parityB. distributes the parity onto every available disk in the arrayC. distributes two different parities onto every available disk in the arrayD. usually has the highest cost per GB of usable space because it duplicates the dataE. has moderate costs per GB because it uses the capacity of one disk for parity per array
Answer: B, E
QUESTION: 4Which Fibre Channel topology is used for host connection with a single MSA Hub 2/3? HP2-K08
A. fabricB. multipathC. dual loopD. arbitrated loop
Answer: D
QUESTION: 5Which drive type is best for holding large amounts of reference data?
A. ATAB. SCSIC. SATAD. Fibre Channel
Answer: C
QUESTION: 6What is the operational configuration limit for Secure Path 4.0c for Windows in an MSAstorage environment? (Select two.)
A. a maximum of 20 hosts per set of shared storage systems (per profile)B. a maximum of 128 hosts per set of shared storage systems (per profile)C. a maximum of 256 storage systems shared by a set of hosts (per profile)D. a maximum of 32 LUNS per target with a maximum of two paths per LUNE. a maximum of 128 LUNS per target with a maximum of two paths per LUN
Answer: B, D
QUESTION: 7How can you extend the storage capacity of a logical drive using the Array ConfigurationUtility? (Select two.)
A. Add a hot spare to the array.B. Add a new disk to the logical drive.C. Add unused space from any array to the logical drive.D. Add a new disk to the array where the logical drive resides. HP2-K08
E. Add unused space from the array where the logical drive resides.
Answer: D, E
QUESTION: 8Which statement about MSA-supported multipath software is correct?
A. The QLogic Multipath Driver is required for Linux operating systems.B. HP Secure Path is required for all MSA-supported operating systems.C. The QLogic Multipath Driver cannot be used for Linux operating systems.D. HP Secure Path and the Microsoft Multipath I/O driver (MPIO) can be used for allMSA-supported operating systems.
Answer: A
QUESTION: 9What is the Storage Management Utility?
A. a replacement for the Array Configuration UtilityB. an alternate management tool for MSA1xxx systemsC. a dedicated management tool for MSA1510i systemsD. a replacement for the MSA1510i Command Line Interface
Answer: C
QUESTION: 10Which rule applies for spare drive configuration with the Storage Management Utility fortheMSA1510i?
A. A spare disk must be the same speed as the other drives in the array.B. A spare disk can be mixed with SCSI and SATA drives in the same array.C. A spare disk must be the same size (or smaller) as the other drives in the array.D. A spare disk must be the same type (SCSI or SATA) as the other drives in the array.
Answer: D
Original Resource :
Visit HP2-K08 Link : HP2-K08 Download PDF Link : HP2-K08
iAutoblog the premier autoblogger software
1:41 AM | | 0 Comments
HP HP2-K08 Free Training - Education - Study Techniques
Supporting the MSA1000, 1500cs & 1510i HP2-K08 Test
HP2-K08
QUESTION: 1What is a characteristic of the read-ahead caching mechanism?
A. Every I/O goes directly to the respective disk.B. The data read from the disks stays in cache until it reaches a threshold.C. Every I/O goes into the RAID controller cache and in a background operation tothe respective disk.D. The RAID controller reads more data than requested from the disks, predicting thenext read from the host that needs this additional data.
Answer: C
QUESTION: 2Which statement is true regarding a dual-path configuration with a single controller?
A. It is not supported.B. It requires Secure Path software.C. It is supported without Secure Path software.D. It requires the Redundancy Manager software.
Answer: C
QUESTION: 3What are two functions of RAID level 5? (Select two.)
A. uses only one physical disk in the array for parityB. distributes the parity onto every available disk in the arrayC. distributes two different parities onto every available disk in the arrayD. usually has the highest cost per GB of usable space because it duplicates the dataE. has moderate costs per GB because it uses the capacity of one disk for parity per array
Answer: B, E
QUESTION: 4Which Fibre Channel topology is used for host connection with a single MSA Hub 2/3? HP2-K08
A. fabricB. multipathC. dual loopD. arbitrated loop
Answer: D
QUESTION: 5Which drive type is best for holding large amounts of reference data?
A. ATAB. SCSIC. SATAD. Fibre Channel
Answer: C
QUESTION: 6What is the operational configuration limit for Secure Path 4.0c for Windows in an MSAstorage environment? (Select two.)
A. a maximum of 20 hosts per set of shared storage systems (per profile)B. a maximum of 128 hosts per set of shared storage systems (per profile)C. a maximum of 256 storage systems shared by a set of hosts (per profile)D. a maximum of 32 LUNS per target with a maximum of two paths per LUNE. a maximum of 128 LUNS per target with a maximum of two paths per LUN
Answer: B, D
QUESTION: 7How can you extend the storage capacity of a logical drive using the Array ConfigurationUtility? (Select two.)
A. Add a hot spare to the array.B. Add a new disk to the logical drive.C. Add unused space from any array to the logical drive.D. Add a new disk to the array where the logical drive resides. HP2-K08
E. Add unused space from the array where the logical drive resides.
Answer: D, E
QUESTION: 8Which statement about MSA-supported multipath software is correct?
A. The QLogic Multipath Driver is required for Linux operating systems.B. HP Secure Path is required for all MSA-supported operating systems.C. The QLogic Multipath Driver cannot be used for Linux operating systems.D. HP Secure Path and the Microsoft Multipath I/O driver (MPIO) can be used for allMSA-supported operating systems.
Answer: A
QUESTION: 9What is the Storage Management Utility?
A. a replacement for the Array Configuration UtilityB. an alternate management tool for MSA1xxx systemsC. a dedicated management tool for MSA1510i systemsD. a replacement for the MSA1510i Command Line Interface
Answer: C
QUESTION: 10Which rule applies for spare drive configuration with the Storage Management Utility fortheMSA1510i?
A. A spare disk must be the same speed as the other drives in the array.B. A spare disk can be mixed with SCSI and SATA drives in the same array.C. A spare disk must be the same size (or smaller) as the other drives in the array.D. A spare disk must be the same type (SCSI or SATA) as the other drives in the array.
Answer: D
Original Resource :
Visit HP2-K08 Link : HP2-K08 Download PDF Link : HP2-K08
iAutoblog the premier autoblogger software
1:34 AM | | 0 Comments
HP HP2-K08 Free Training - Education - Study Techniques
Supporting the MSA1000, 1500cs & 1510i HP2-K08 Test
HP2-K08
QUESTION: 1What is a characteristic of the read-ahead caching mechanism?
A. Every I/O goes directly to the respective disk.B. The data read from the disks stays in cache until it reaches a threshold.C. Every I/O goes into the RAID controller cache and in a background operation tothe respective disk.D. The RAID controller reads more data than requested from the disks, predicting thenext read from the host that needs this additional data.
Answer: C
QUESTION: 2Which statement is true regarding a dual-path configuration with a single controller?
A. It is not supported.B. It requires Secure Path software.C. It is supported without Secure Path software.D. It requires the Redundancy Manager software.
Answer: C
QUESTION: 3What are two functions of RAID level 5? (Select two.)
A. uses only one physical disk in the array for parityB. distributes the parity onto every available disk in the arrayC. distributes two different parities onto every available disk in the arrayD. usually has the highest cost per GB of usable space because it duplicates the dataE. has moderate costs per GB because it uses the capacity of one disk for parity per array
Answer: B, E
QUESTION: 4Which Fibre Channel topology is used for host connection with a single MSA Hub 2/3? HP2-K08
A. fabricB. multipathC. dual loopD. arbitrated loop
Answer: D
QUESTION: 5Which drive type is best for holding large amounts of reference data?
A. ATAB. SCSIC. SATAD. Fibre Channel
Answer: C
QUESTION: 6What is the operational configuration limit for Secure Path 4.0c for Windows in an MSAstorage environment? (Select two.)
A. a maximum of 20 hosts per set of shared storage systems (per profile)B. a maximum of 128 hosts per set of shared storage systems (per profile)C. a maximum of 256 storage systems shared by a set of hosts (per profile)D. a maximum of 32 LUNS per target with a maximum of two paths per LUNE. a maximum of 128 LUNS per target with a maximum of two paths per LUN
Answer: B, D
QUESTION: 7How can you extend the storage capacity of a logical drive using the Array ConfigurationUtility? (Select two.)
A. Add a hot spare to the array.B. Add a new disk to the logical drive.C. Add unused space from any array to the logical drive.D. Add a new disk to the array where the logical drive resides. HP2-K08
E. Add unused space from the array where the logical drive resides.
Answer: D, E
QUESTION: 8Which statement about MSA-supported multipath software is correct?
A. The QLogic Multipath Driver is required for Linux operating systems.B. HP Secure Path is required for all MSA-supported operating systems.C. The QLogic Multipath Driver cannot be used for Linux operating systems.D. HP Secure Path and the Microsoft Multipath I/O driver (MPIO) can be used for allMSA-supported operating systems.
Answer: A
QUESTION: 9What is the Storage Management Utility?
A. a replacement for the Array Configuration UtilityB. an alternate management tool for MSA1xxx systemsC. a dedicated management tool for MSA1510i systemsD. a replacement for the MSA1510i Command Line Interface
Answer: C
QUESTION: 10Which rule applies for spare drive configuration with the Storage Management Utility fortheMSA1510i?
A. A spare disk must be the same speed as the other drives in the array.B. A spare disk can be mixed with SCSI and SATA drives in the same array.C. A spare disk must be the same size (or smaller) as the other drives in the array.D. A spare disk must be the same type (SCSI or SATA) as the other drives in the array.
Answer: D
Original Resource :
Visit HP2-K08 Link : HP2-K08 Download PDF Link : HP2-K08
iAutoblog the premier autoblogger software
1:37 AM | | 0 Comments
Online affordable xmpp server and jabber server - Business - Management
The Internet is flooded with sites providing hosting services. In the store, you can use these sites to download your Web sites on the World Wide Web. You can take the services of a dedicated server or rent server space is very cheap and affordable price. Some hosting, such as personal Web hosting is free, but in this limited function. Web sites running on two different types of platforms, Windows-based platforms, and the second are a LINUX based platform. LINUX-based platform is relatively cheaper compared to beat those based on the platform. This is because Linux is an open source operating system, which means that you can download it for free from the Internet. xmpp server generally found to be very stable and solid.There are different functions, such as the place of storage, bandwidth and server access granted to you by LINUX VPS. In addition, jabber server offers better security as your space allocated to a server that is separate from other users. You can also ensure that there will be no abuse of the system by other users who have an impact on the functioning of Your Web site. On some servers, because too many users, which is always high. This means that your website will take time, high load, you may end up adversely affecting your business. Platform based on Linux are very powerful, downtime almost 99.9%.XMPP is the Extensible Messaging and presence Protocol. Previously it was known as the jabber server. The main purpose is to provide extensible xmpp instant messaging (IM). It is also used for maintenance and presence information to the contact list. Although it was not originally present, xmpp, was extended to support new features such as voice over the Internet and files. In comparison with other IM protocols, Specialization in xmpp is a protocol for open systems. This means that one service can integrate with other xmpp organizations ' services. Software and most other additional applications are available for free download.Built in XMPP uses a decentralized approach. This means that any person can implement and maintain their xmpp server; there is no central server to control the entire network. There are many security features implemented in xmpp. XMPP servers may be isolated from the public network. This is useful for running an intranet service. Tough safety specifications were xmpp software. Client-server approach is used in xmpp to facilitate communication. In this approach, any two clients will not be able to communicate directly with each other, but will have to communicate through a server. However, unlike some chat services, there is a centralized server controls all communications.You can also try the method of virtual private server hosting for an XMPP server. Extensible Protocol XMPP servers for messaging and presence and is used for message-oriented middleware applications. It was developed primarily in its form by an online community called open source Jabber server and therefore was n amed Jabber after it. Jabber or XMPP server was originally designed for instant messaging, contact list management, presence information and file transfer methods. Safety features and flexibility of XMPP servers have made very compatible with the environment of VPS Server.
iAutoblog the premier autoblogger software
1:37 AM | | 0 Comments